Search results for "Standard deviation"
showing 10 items of 282 documents
SMOS Level-2 Soil Moisture Product Evaluation in Rain-Fed Croplands of the Pampean Region of Argentina
2016
A field campaign was carried out to evaluate the Soil Moisture (SM) MIR-SMUDP2 product (v5.51) generated from the data of the Microwave Imaging Radiometer using Aperture Synthesis (MIRAS) aboard the Soil Moisture and Ocean Salinity (SMOS) mission. The study area was the Pampean Region of Argentina, which was selected because it is a vast area of flatlands containing quite homogeneous rain-fed croplands, which are considered SMOS nominal land uses and hardly affected by radio-frequency interference contamination. Transects of ground handheld SM measurements were performed using ThetaProbe ML2x probes within four Icosahedral Snyder Equal Area Earth (ISEA) grid nodes, where permanent SM statio…
GIGJ: a crustal gravity model of the Guangdong Province for predicting the geoneutrino signal at the JUNO experiment
2019
Gravimetric methods are expected to play a decisive role in geophysical modeling of the regional crustal structure applied to geoneutrino studies. GIGJ (GOCE Inversion for Geoneutrinos at JUNO) is a 3D numerical model constituted by ~46 x 10$^{3}$ voxels of 50 x 50 x 0.1 km, built by inverting gravimetric data over the 6{\deg} x 4{\deg} area centered at the Jiangmen Underground Neutrino Observatory (JUNO) experiment, currently under construction in the Guangdong Province (China). The a-priori modeling is based on the adoption of deep seismic sounding profiles, receiver functions, teleseismic P-wave velocity models and Moho depth maps, according to their own accuracy and spatial resolution. …
Vicarious Calibration of Landsat-8 Thermal Data Collections and its Influence on Split-Window Algorithm Validation
2018
Landsat 8 (L8) satellite was launched on February 11, 2013 with two thermal bands located in the atmospheric window between $10-12\ \mu \mathrm{m}$ . Continuous monitoring of the Thermal Infrared Sensor (TIRS) onboard of L8 was performed over two Spanish test sites – Barrax and Donana – in order to contribute to the quality of TIRS data. In this work, a Vicarious Calibration (VC) of the TIRS bands was performed between years 2013–2016 in order to assess the new Stray Light (SL) data correction. The results of VC show us that band 10 and 11 provide accurate results (bias near to zero, and precision around 0.8 K) which is an improvement – especially for band 11 – in comparison to preprocessed…
A Comparison between Drifter and X-Band Wave Radar for Sea Surface Current Estimation
2016
This paper deals with exploitation of the wave radar system for sea surface current estimation in a coastal zone. In particular, we present the results of the processing of the radar data collected by an X-band marine radar installed in Capo Granitola site, which is located in the south-west part of Sicily, on 15 May 2015. The effectiveness of the data processing is analyzed by comparing the wave radar estimated sea surface current with that provided by the Lagrangian drifters along its movement trajectory. During the measurement campaign, three drifter releases are carried out and for each one the comparison is provided in terms of the mean error and standard deviation. In addition, we rep…
Influence of infrared camera model and evaluator reproducibility in the assessment of skin temperature responses to physical exercise.
2021
Infrared thermography (IRT) has been gaining in popularity in clinical and scientific research due to the increasing availability of affordable infrared cameras. This study aims to determine the similarity of measurement performance between three models of IRT camera during assessment of skin temperature before and after physical exercise. Three models of FLIR thermographic cameras (E60bx, Flir-One Pro LT, and C2) were tested. Thermal images were taken of the foot sole, anterior leg, and anterior thigh from 12 well-trained men, before and after a 30-min run on a treadmill. Image files were blinded and processed by three evaluators to extract the mean, maximum, and standard deviation of skin…
Green methodology for quality control of elemental content of infant milk powder
2019
Abstract A green methodology for the direct determination of elemental content in infant milk powder samples from 0 to 3 years was developed. A portable energy dispersive X-ray fluorescence (ED-XRF) tool has been used as a direct method for the quantification of five essential elements (Ca, K, Fe, Cu and Zn). For analysis pellets from 0.8 g of each sample weight were made and analyzed. Due to the high dependence of the ED-XRF signal with the sample matrix, external calibrations using cocoa powder diluted with glucose were performed. Infant milk samples were diluted with lactose and the signals were interpolated in the external calibrations. Concentrations obtained by ED-XRF were compared wi…
Heterogeneous Indicators of Cognitive Performance and Performance Variability Across the Lifespan
2020
Reaction time (RT) and RT variability are core components of cognitive performance that can be captured through brief and easy-to-administer tasks of simple RT and choice RT. The current study aims to describe age-related differences in cognitive performance, toward better characterizing normative performance across the lifespan. We examined mean and variability of response times on a simple RT and choice RT tasks in a large and diverse web-based sample (10,060 visitors to TestMyBrain.org). We also examined lifespan-related differences in response time variability using multiple different approaches (raw variability, mean scaled variability, and mean residualized variability). These analyse…
Melanoma-Nevus Discrimination Based on Image Statistics in Few Spectral Channels
2016
The purpose of this paper is to offer a method for discrimination of cutaneous melanoma from benign nevus, founded on analysis of skin lesion image. At the core of method is calculation of mean and standard deviation of pixel optical density values for a few narrow spectral bands. Calculated values are compared with discriminating thresholds derived from a set of images of benign nevi and melanomas with known diagnosis. Classification is done applying weighted majority rule to results of thresholding. Verification against the available multispectral images of 32 melanomas and 94 benign nevi has shown that the method using three spectral bands provided zero false negative and four false posi…
Genetically elevated gamma-glutamyltransferase and Alzheimer's disease
2018
Observational epidemiological evidence supports a linear and independent association between serum gamma-glutamyltransferase (GGT) concentrations and the risk of Alzheimer's disease (AD). However, the causality of this association has not been previously investigated. We sought to assess the causal nature of this association using a Mendelian randomization (MR) approach. Using inverse-variance weighted MR analysis, we assessed the association between GGT and AD using summary statistics for single nucleotide polymorphism (SNP)-AD associations obtained from the International Genomics of Alzheimer's Project of 17,008 individuals with AD and 37,154 controls. We used 26 SNPs significantly associ…
Bolton ratios in Portuguese subjects among different malocclusion groups
2018
Background Several methods have been described to estimate inter-arch tooth size relationship, such as Bolton's ratios. The aims of this study were to verify the validity of Bolton indexes in a sample of untreated Portuguese subjects based on Angle classification and to evaluate the gender difference. Material and Methods 168 pre-treatment dental casts of orthodontics Portuguese subjects (59 males and 109 females) with different occlusions were used, which were selected randomly from 541 consecutively treated orthodontic patients. The mesiodistal widths from first molar to first molar were measured on each pre-treatment cast to the nearest 0.01 mm using digital caliper, and Bolton's anterio…